Usage/Application | Hospital Waste Decompostion |
Type Of Incinerator | Hospital Waste Incinerator |
Power Source | Electrical |
Waste Type | PPE KIT |
Capacity | 5 KG |
Brand | HYGIENE N HUMAN |
Material | Mild Steel |
I Deal In | New Only |
Additional Information:
View Complete details
Minimum Order Quantity: 1 Piece
Product Brochure
Usage/Application | For Hospital Hazardous Waste |
Type Of Incinerator | Hospital Waste Incinerator |
Power Source | Diesel |
Waste Type | Ash |
Capacity | 50 KG |
Brand | HYGIENE N HUMAN |
Burning Ability | 300 Kg/time |
Average Burn Out Time | 1 HOUR |
Material | Mild Steel |
Country of Origin | Made in India |
The Biomedical Waste incinerator and Medical waste incinerator is one of the treatment and safe disposal of the bio-medical waste generated from the hospitals, veterinary facilities, medical research facilities etc.
These wastes include both infectious medical wastes as well as non-infectious, general housekeeping wastes. Bio-medical incinerator is equipped with necessary air pollution control devices (APCD) for removal of pollutants from flue gases to achieve desired level. The flue gases are cleaned for removal of pollutants and gaseous compounds by passing through various air pollution control devices (APCD) before releasing them into the atmosphere through stacks filter are provided to make incinerator complete pollution free, smoke, colorless Treated, odorless treated.
Following design criteria adopted for better performance: The bio-medical waste incineration is designed for primary and secondary combustion systems. Total Organic carbon content in the slag/bottom ash is less than 1% or their loss on ignition is less than 3% of the dry weight as prescribed. The double chamber incinerator is preferably be designed on “controlled-air” incineration principle, as particulate matter emission is low in such incinerator. Air supply in the primary and secondary Chamber may be regulated between 30%-80% and 170%-120% of stiochiometric requirement respectively.
In primary chamber, primary air is admitted near. Suitable flow measurement device is provided on the primary and secondary air ducting. The combustion air is supplied through a separate forced draft fan after accounting for the air supplied through burners. The primary chamber is to avoid leakage of gaseous emissions from the chamber and for safety reasons.
The secondary chamber is properly designed so as to facilitate a minimum of two seconds residence time to ensure combustion of the gas flow, unburnt material such as volatiles, smoke and soot. For the estimation of residence time in the secondary chamber its volume calculated starting from the secondary burner tip to the thermocouple. Incinerator walls are protected with insulated fire bricks/refractory system. The refractory lining of the chamber is strong enough to sustain thermal shocks i.e. minimum temperature 1000° C in the primary chamber and upto 1450°C in the secondary chamber. The refractory & insulation brick is have suitable thickness.